Contact diaries versus wearable proximity sensors in measuring contact patterns at a conference: method comparison and participants' attitudes.

Smieszek, Timo; Castell, Stefanie; Barrat, Alain; Cattuto, Ciro; White, Peter J; Krause, GĂ©rard
BACKGROUND Studies measuring contact networks have helped to improve our understanding of infectious disease transmission. However, several methodological issues are still unresolved, such as which method of contact measurement is the most valid. Further, complete network analysis requires data from most, ideally all, members of a network and, to achieve this, acceptance of the measurement method. We aimed at investigating measurement error by comparing two methods of contact measurement - paper diaries vs. wearable proximity sensors - that were applied concurrently to the same population, and we measured acceptability. METHODS We investigated the contact network of one day of an epidemiology conference in September 2014. Seventy-six participants wore proximity sensors throughout the day while concurrently recording their contacts with other study participants in a paper-diary; they also reported on method acceptability. RESULTS There were 329 contact reports in the paper diaries, corresponding to 199 contacts, of which 130 were noted by both parties. The sensors recorded 316 contacts, which would have resulted in 632 contact reports if there had been perfect concordance in recording. We estimated the probabilities that a contact was reported in a diary as: P = 72 {\%} for {\textless}5 min contact duration (significantly lower than the following, p {\textless} 0.05), P = 86 {\%} for 5-15 min, P = 89 {\%} for 15-60 min, and P = 94 {\%} for {\textgreater}60 min. The sets of sensor-measured and self-reported contacts had a large intersection, but neither was a subset of the other. Participants' aggregated contact duration was mostly substantially longer in the diary data than in the sensor data. Twenty percent of respondents ({\textgreater}1 reported contact) stated that filling in the diary was too much work, 25 {\%} of respondents reported difficulties in remembering contacts, and 93 {\%} were comfortable having their conference contacts measured by sensors. CONCLUSION Reporting and recording were not complete; reporting was particularly incomplete for contacts {\textless}5 min. The types of contact that both methods are capable of detecting are partly different. Participants appear to have overestimated the duration of their contacts. Conducting a study with diaries or wearable sensors was acceptable to and mostly easily done by participants. Both methods can be applied meaningfully if their specific limitations are considered and incompleteness is accounted for.
Research areas:
Year:
2016
Type of Publication:
Article
Keywords:
Acceptability; Contact diary; Contact network; Infection transmission; Infectious disease; Measurement error; Network epidemiology; Network model; Proximity sensor; RFID
Journal:
BMC infectious diseases
Volume:
16
Pages:
341
ISSN:
1471-2334
DOI:
10.1186/s12879-016-1676-y
Hits: 1174

We use cookies to improve our website and your experience when using it. Cookies used for the essential operation of this site have already been set. To find out more about the cookies we use and how to delete them, see our privacy policy.

  I accept cookies from this site.
EU Cookie Directive Module Information